RJ683XAC/DC Voltage Withstand and Insulation Tester
RJ683X AC/DC Voltage Withstand and Insulation Tester, has the test functions of AC Voltage withstand, DC Voltage withstand, insulation resistance and it can provide fast and efficient safety testing for battery modules, pack, new energy vehicles, household appliances, power electronics and other products.
Main feature
Meet the test requirements of CCC, IEC, EN, VDE, BS, UL, JIS and other mandatory electrical safety standards
Ac withstand voltage, DC withstand voltage, insulation resistance items automatic connection test
Arc detection function, product test arc alarm output lock, prevent continuous arc discharge product burn caused by irreparable damage
Filter function, for capacitive substance test, can relatively maintain data stability in the test, reduce the data surge caused by capacitor charge and discharge
Discharge function, set the discharge time according to the capacitance, display the discharge process voltage, and intuitively understand the discharge result
30 test groups, each group of 8 test steps, easy to operate
RS232 interface, PLC interface
Technical parameter
Model | RJ6836H | RJ6835H | RJ6833H | ||
AC Volt age With stand Test |
Output Capacity | 500VA (5000V/100mA) |
200VA (5000V/40mA) |
||
Output Voltage | Range/Resolution/Ac curacy | 50V~5000V /1V / ±(2%rdg.+5dgt.) | |||
Voltage Frequency | Range/Accuracy | 50Hz / 60Hz/ ±0.1% | |||
Current lower limit setting | Range | 0.00mA~99.99mA | 0.00mA~40.00mA | ||
Current Upper Limit Setting | Range | 0.00mA~99.99mA | 0.00mA~40.00mA | ||
Time setting | Range/Resolution/Ac curacy | 1.0s~999.9s /0.1s/ ±(0.2%st.+2dgt.) | |||
Current Measurement | Range/Resolution/Ac curacy | 0.10mA~99.99mA 0.01mA ±(2%rdg.+5dgt.) |
0.10mA~40.00mA 0.01mA ±(2%rdg.+5dgt.) |
||
DC volta ge with stand test |
Output Capacity | 60VA(6000V/10mA) | |||
Output Voltage | Range/Resolution/Ac curacy | 50V~6000VDC/1V / ±(3%rdg.+10dgt.) | |||
Current lower limit setting | Range | 0.000mA~9.999mA | |||
Current Upper Limit Setting | Range | 0.000mA~9.999mA | |||
Time setting | Range/Resolution/Ac curacy | 1.0s~999.9s / 0.1s/ ±(0.2%st.+2dgt.) | |||
Current Measurement | Range/Accuracy | 0.000mA~9.999mA/±(2%rdg.+0.2%f.s.(20dgt.)) | |||
Insul ation Resistance Test | Output Voltage | Range/Resolution/Ac curacy | 25V~3000V/ 1V / ±(2%rdg.+5dgt.) | ||
Lower resistance limit setting | Range | 0.3MΩ~99.9MΩ/100MΩ-50000MΩ | |||
Resistance limit setting | Range | 0~50000MΩ | |||
Time setting | Range/Resolution/Ac curacy | 1.0s~999.9s/0.1s/ ±(0.2%st.+2dgt.) | |||
Resistance Measurement | Range/Accuracy | 25V~199V: | |||
0.3M~99.9M | 3%rdg.+3dgt. | ||||
100M~500M | 5%rdg.+5dgt. | ||||
200V~299V: | |||||
0.3M~99.9M~199M | 3%rdg.+3dgt. | ||||
200M~4999M | 8%rdg.+2dgt. | ||||
300V~3000V: | |||||
1M~99.9M~199M | 2%rdg.+3dgt. | ||||
200M~4999M | 5%rdg.+5dgt. | ||||
5000M~9999M | 8%rdg.+2dgt. | ||||
10000M~50000M | 15%rdg.+30dgt. | ||||
Other indicators | Arc detection | 0 off 1~9 (1 is most sensitive) | |||
Low-pass filtering | 0 off 1~6 (step by step) | ||||
External Interfaces | RS232 (Optional: RS485), PLC | ||||
Operating Environment | 0℃~40℃,20%RH~75%RH | ||||
Power Supply | AC220V,50/60Hz | ||||
Net weight | 18kg | ||||
External Dimension | 342mm×133mm×460mm(W×H x D)without foot, foot height 15mm | ||||
Attachment | 1 manual, 1 power cord (1.5 m), 1 communication cable (1.5 m), 1 test line (3 m), 1 D-type connector |