RJ1838HMulti-function Safety Tester

RJ1838H multifunctional safety tester, with AC voltage withstand, DC voltage withstand, insulation resistance, AC ground resistance test functions, for battery modules, pack, new energy vehicles, household appliances, power electronics and other industry products to provide fast and efficient safety combination test.


Multi-function Safety Tester
Main feature
Meet the test requirements of CCC, IEC, EN, VDE, BS, UL, JIS and other mandatory electrical safety standards
Ac withstand voltage, DC withstand voltage, insulation resistance items automatic connection test
Arc detection function, product test arc alarm output lock, prevent continuous arc discharge product burn caused by irreparable damage
Filter function, for capacitive substance test, can relatively maintain data stability in the test, reduce the data surge caused by capacitor charge and discharge
Discharge function, set the discharge time according to the capacitance, display the discharge process voltage, and intuitively understand the discharge result
30 test groups, each group of 8 test steps, easy to operate
RS232 interface, PLC interface, network port communication(LAN)
Technical parameter
Model RJ1838H
Hand in Output capacity 500VA(5000V/100mA)
flow
Resistance to
pressure
measuring
try
Output voltage Range/resolution/accuracy 50V~5000V  /  1V  /  ±(1%rdg.+5dgt.)
Voltage frequency Range/accuracy 50Hz   /  60Hz   ±0.1%
Current Lower limit setting Range 0.000mA~100.0mA

Upper current setting Range 0.000mA~100.0mA
Time Settings Range/resolution/accuracy 1.0s ~999.9s /0.1s/±(0.1%rdg.+5dgt.)
Current measurement Range/resolution/accuracy 0.001mA~100.0 mA  /0.001mA、0.01mA、0.1mA /
±(1%rdg.+5dgt.)
straight
flow
Resistance to
pressure
measuring
try
Output capacity 120 VA (6000V/20mA)
Output voltage Range/resolution/accuracy 25V~6000V  /  1V  /  ±(1%rdg.+5dgt.)
Current lower limit setting Range 0.0μA~20000μA

Upper current setting Range 1.0μA~20000μA
Time Settings Range/resolution/precision 1.0s ~999.9s /0.1s /±(0.1%rdg.+5dgt.)
Current measurement Range/resolution/accuracy 1.0μA~9999μA /10.00~20.00mA
/0.1μA、1μA、0.01mA / ±(1%rdg.+5dgt.)
Contact detection current On/off  0.1μA~999.9μA/1000μA~20000μA
Maximum capacitive load 1μF<1000V , 0.75μF<2KV , 0.5uF<3KV ,0.8μF < 4KV,0.4μF < 5KV
absolutely
edge
electricity
The resistance
measuring
try
Output capacity 120 VA  (6000V/20mA)
Output voltage Range/resolution/accuracy 25V~6000V  /  1V  /  ±(1%rdg.+5dgt.)
Resistance lower limit setting Radius 0.100MΩ~100000 MΩ
Resistance Upper limit setting Range 0.100MΩ~100000 MΩ;
0.000 indicates that the upper limit is not judged

Time setting Range/resolution/precision 1.0s ~999.9s /0.1s /±(0.1%rdg.+5dgt.)
Resistance measurement Range/accuracy 25V~99V:
0.100MΩ ~500 MΩ ±(15%rdg.+2dgt.)
100V~499V:
0.100MΩ~2.000GΩ   ±(5%rdg.+2dgt.)
500V~799V:
1.000MΩ~999.9MΩ ±(2%rdg.+2dgt.)
1.000GΩ~9.999GΩ ±(5%rdg.+2dgt.)
10.00GΩ~50.00GΩ ±(15%rdg.+2dgt.)
800V~6000V:
1.000MΩ~999.9MΩ ±(2%rdg.+2dgt.)
1.000GΩ~9.999GΩ ±(5%rdg.+2dgt.)
10.00GΩ~100.00GΩ ±(15%rdg.+2dgt.)
Maximum capacitive load 1μF<1000V , 0.75μF<2KV , 0.5μF<3KV , 0.08μF < 4KV,  0.04μF < 5KV
Ground Resistance Test Rated output Range 240VA(40A/150mΩ)
Output current Range/resolution/error 2.00A~40.0A/0.01A、0.1A/±(1%rdg.+2dgt.)
Current fluctuation Range ≤0.4%rdg./min
Output voltage Range/resolution/error 2.00~8.00V /0.01V/±(1%rdg.+2dgt.)
Output frequency Range/accuracy 50Hz   /  60Hz   ±0.1%
Upper resistance setting Range/resolution/error 10.0mΩ~600mΩ /  0.1mΩ  1mΩ
Lower resistance setting Range/resolution/error 0.0mΩ~100mΩ /  0.1mΩ  1mΩ
Resistance lower limit setting Range 2.00A~9.99A:
10.0mΩ ~99.9mΩ       ±(1%rdg.+1mΩ)
100mΩ ~600mΩ     ±(1%rdg.+2dgt.)
10.0A~19.9A:
10.0mΩ~99.9mΩ ±(1%rdg.+1mΩ)
100mΩ ~300mΩ  ±(1%rdg.+2dgt.)
20.0A~29.9A:
10.0mΩ ~99.9mΩ   ±(1%rdg.+1mΩ)
100mΩ ~200mΩ ±(1%rdg.+2dgt.)
30.0A~40.0A:
10.0mΩ ~99.9mΩ ±(1%rdg.+1mΩ)
100mΩ ~150mΩ ±(1%rdg.+2dgt.)
Voltage measurement Range/resolution/error 2.00~8.00V / 0.01V /±(1%rdg.+2dgt.)
Voltage display mode
Test time Range/resolution/error 1.0s ~999.9s /0.1s /±(0.1%rdg.+5dgt.)
its
he
Refers to the
mark
Resistance compensation Range/resolution/error (0 ~ 200)M Ω
Arc detection 0 off  1~9 (1 is most sensitive)
Filter function on/ off  
External interface RS232(Optional:RS485),PLC,LAN interface
Use environment 0℃~40℃,20%RH~75%RH
Power supply interface AC220V,50/60Hz
Net weight 27kg
Exterior dimensions 436mm x 133mm x 596mm (WxHxD) without foot, foot height 15mm
Attachment 1 manual, 1 power cord (1.5m), 1 communication cable (1.5m), 1 set of test wire (3 m), 1 set of ground test wire (1.5m), 1 D-type connector


在线客服