RJ8921PAC/DC Power Measuring Instrument

RJ8921P AC/DC Power Measuring Instrument (referred to as the measuring instrument) with ADI high-performance ARM71 series controller as the core, using pure resistance sampling, no distortion, suitable for AC/DC true RMS measurement, widely used in single-phase power equipment, voltage, current, power, power factor, frequency, electrical energy, time and other electrical parameters measurement, measurement of a wide range of 3-window LED bright display, operation, simple and practical, standard with serial communication, simple and practical, standard with serial communication.


AC/DC Power Measuring Instrument
Main feature
High measurement accuracy of 0.2 class
TTRMS Value RMS AC/DC test
Minimum measurement current of 2mA, and it can realize measurement of standby power consumption
Fast measurement speed, the maximum refresh rate could reach 200 ms
Voltage, current ratio setting function, easy to extend the measurement range
Voltage, current, power overrun sound and light alarm function, which can meet the need to quickly identify abnormal products in the field
RS-232 or RS-485 serial communication port for easy test automation and data transfer
Beautifully designed appearance, small size and light weight
Technical parameter
Model RJ8921P
Measuring channel Single-phase
Measured parameters Voltage U, current I, active power P, reactive power Q, apparent power S, power factor λ, phase angle φ,voltage frequency f, electric energy Wh, electric energy timing Time
Peak factor at full scale 1.6
Voltage rated range 600V
Current rated range 5A card: 1A/5A 20A card: 1A/20A
50A card: 1A/50A
Voltage accuracy range AC/DC:3~600V
Current accuracy range AC/DC:1mA~1A/40A(Option:0.1mA~100mA/5A)
Voltage/Current measurement accuracy DC, 45Hz~65Hz:±(0.1%rdg.+0.1%f.s.)
Active power measurement accuracy DC    ± (0.1%rdg.+0.1%f.s.)

PF>0.5: ±(0.1%rdg.+0.1%f.s.)

PF≤0.5: ±(0.25%rdg.+0.25%f.s.)
Reactive power PF=0:±(0.25%rdg.+0.25%f.s.)
Active power resolution 0.001W
Power Factor Range ±(0.100~1.000)
Power factor accuracy ±0.01 (Both voltage amplitude and current amplitude should be greater than
10% of the corresponding range)
Frequency  measurement range DC,45Hz~65Hz
Frequency  measurement accuracy ±(0.1%rdg.) (Voltage amplitude should be greater than 10% of the range)
Electrical energy range 0~999999MWh
Electrical energy Accuracy PF>0.5:±(0.1%rdg.+0.1%f.s.)

PF≤0.5:±(0.25%rdg.+0.25%f.s.)
Electrical energy timing 999 hours, 59 minutes, 59 seconds (±0.05%)
Electrical Energy Timing Accuracy ±(0.05%rdg.)
Voltage/Current Ratio 1~2000
Data update cycle 0.25,0.5,1[s]
Alarm Function 5 groups, voltage, current, power upper/lower limit, threshold setting
Control Interface RS232 (optional:RS485) PLC (optional)
Operating Environment 0℃~40℃,20%RH~75%RH
Power Supply AC220V,50/60Hz
Net weight 3.7kg
External Dimension 213mm×88mm×386mm (W×H×D) without foot, foot height 15mm
Attachment 1 instruction manual, 1 power cord (1.5 meters), 1 communication cable (1.5meters) 