RJ6000 safety comprehensive test system is a safety testing equipment integrating safety comprehensive tester, industrial control machine and upper computer software. It is designed for safety testing and data traceability of electrical products, and has functions such as data storage, query, export and qualification rate statistics.


Safety Comprehensive Test System
Main feature
Safety Performance Comprehensive Tester: Grounding, insulation, Voltage withstand, leakage safety test, voltage, current, power electrical parameter test
Programmable variable frequency power supply: Provide working power supply for the product under test
All-in-one computer: Setting, displaying, storing and querying test data
Technical parameter
Model RJ6000
Ground resistance test Open circuit output voltage <12V
Output Current Setting Range/Resolution/Accuracy 3A~30A      / 1A     / ±(3%rdg.+0.18A)
Current Frequency Setting Range/Accuracy 50Hz / 60Hz           / ±0.1%
Resistance limit setting Range/Resolution 3A~10A: 10mΩ~600mΩ    /  1mΩ
11A~25A:10mΩ~300mΩ    /  1mΩ
26A~30A:10mΩ~200mΩ    /  1mΩ
Lower resistance limit setting Range/Resolution 0mΩ~100mΩ / 1mΩ
Time setting Range/Resolution/Accuracy 1.0s~999.9s / 0.1s /  ±(0.1%st.+0.5dgt.)
Resistance Measurement Range/Resolution/Accuracy 1mΩ~600mΩ / 1mΩ /  ±(3%rdg.+5dgt.)
Insulation Resistance Test Output Capacity 2VA(1000V/2mA)
Output Voltage Range/Resolution/Accuracy 200V~1000V  /   1V /  ±(3%rdg.+3dgt.)
Lower resistance limit setting Range/Resolution 0.3MΩ~99.9MΩ/100MΩ~3000MΩ/ 0.1MΩ/1MΩ
Resistance limit setting Range/Resolution 0.0MΩ~99.9MΩ/100MΩ~3000MΩ/ 0.1MΩ/1MΩ
Time setting Range/Resolution/Accuracy 1.0s~999.9s / 0.1s  /  ±(0.1%st.+0.5dgt.)
Resistance Measurement Range/Resolution/Accuracy 1.0 MΩ~99.9MΩ/0.1MΩ/±(3%rdg.+3dgt.)
100 MΩ~2000MΩ/ 1MΩ /±(8%rdg.+8dgt.)
AC Voltage Withstand Test Output Capacity 100VA(5000V/20mA)
Output Voltage Range/Resolution/Accuracy 300V~5000V    /  1V  / ±(3%rdg.+10dgt.)
Voltage Frequency Range/Accuracy 50Hz / 60Hz       / ±0.1%
Current lower limit setting Range/Resolution 0.00mA~10.00mA  /0.01mA
Current Upper Limit Setting Range/Resolution 0.10mA~20.00mA  /0.01mA
Time setting Range/Resolution/Accuracy 2.0s~999.9s  / 0.1s /   ±(0.1%st.+0.5dgt.)
Current Measurement Range/Resolution/Accuracy 0.10mA~20.00mA/0.01mA/±(3%rdg.+3dgt.)
DC voltage withstand test Produced grain weight 40VA(4000V/10mA)
Output Voltage Range/Resolution/Accuracy 300V~4000V    /  1V  /±(3%rdg.+10dgt.)
Current lower limit setting Range/Resolution 0.000mA~9.999mA  /0.001mA
Current Upper Limit Setting Range/Resolution 0.010mA~9.999mA  /0.001mA
Time setting Range/Resolution/Accuracy 1.0s~999.9s  / 0.1s / ±(0.1%st.+0.5dgt.)
Current Measurement Range/Resolution/Accuracy 0.001mA~9.999mA/0.001mA/±(3%rdg.+5dgt.)
Leakage current test Current lower limit setting Range/Resolution 0μA ~9999μA / 1μA
Current Upper Limit Setting Range/Resolution 0μA ~9999μA / 1μA
Time setting Range/Resolution/Accuracy 2.0s~999.9s   /  0.1s/±(1%st.+2dgt.)
Voltage measurement Range/Resolution/Accuracy 60V~280V      /  1V  /±(0.5%rdg.+2dgt.)
Current Measurement Range/Resolution/Accuracy 50μA ~9999μA / 1μA /
DC   ~10kHz: ±(3%rdg.+10dgt.)
10kHz~ 1MHz: ±(5%rdg.+50dgt.)
Start-up test Current upper and lower limit settings Range/Resolution 0.00A~25.00A  /  0.01A
Time setting Range/Resolution/Accuracy 1.0s~999.9s   /  0.1s/±(1%st.+2dgt.)
Middle Voltage measurement Range/Resolution/Accuracy 60V~280V      /  1V  /±(0.5%rdg.+2dgt.)
Current Measurement Range/Resolution/Accuracy 0.030A~3.999A /0.001A/±(0.5%rdg.+20dgt.)
4.00A~25.00A  /0.01A /±(0.5%rdg.+2dgt.)
Power Test Power upper and lower limit settings Range/Resolution 0W~6000W      /  1W
Time setting Range/Resolution/Accuracy 1.0s~999.9s   /  0.1s/ ±(1%st.+2dgt.)
Voltage measurement Range/Resolution/Accuracy 60V~280V      /  1V  / ±(0.5%rdg.+2dgt.)
Current Measurement Range/Resolution/Accuracy 0.030A~3.999A /0.001A / ±(0.5%rdg.+20dgt.)
4.00A~25.00A  /0.01A / ±(0.5%rdg.+2dgt.)
Power Measurement Range/Resolution/Accuracy 30.0W~199.9W   /0.1W / ±(0.5%rdg.+50dgt.)
200.0W~6000.0W  /0.1W  /±(0.5%rdg.+30dgt.)
Power Factor Measurement Range/Resolution/Accuracy 0.10~1.00     /0.01 / ±(2%rdg.+2dgt.)
Open-short circuit Resistance upper and lower limit settings Range/Resolution 1Ω~500Ω     / 1Ω
Time setting Range/Resolution/Accuracy 1.0s~999.9s   /  0.1s/ ±(1%st.+2dgt.)
Resistance Measurement Range/Resolution/Accuracy 1Ω~500Ω     / 1Ω  / ±(2%rdg.+2dgt.)
Other indicators External Interfaces RS232, PLC, power supply communication interface, alarm light interface
Operating Environment 0℃~40℃,20%RH~75%RH
Power Supply AC220V,50/60Hz
Net weight 25.3kg
External Dimension 449mm×151mm×600mm(W×HxD) without foot, foot height 15mm
Attachment 1 instruction manual, 1 power cable (1.5m), 1 communication cable (1.5m), 1 set of test cable.