RJ6000Safety Comprehensive Test System
RJ6000 safety comprehensive test system is a safety testing equipment integrating safety comprehensive tester, industrial control machine and upper computer software. It is designed for safety testing and data traceability of electrical products, and has functions such as data storage, query, export and qualification rate statistics.
Main feature
Safety Performance Comprehensive Tester: Grounding, insulation, Voltage withstand, leakage safety test, voltage, current, power electrical parameter test
Programmable variable frequency power supply: Provide working power supply for the product under test
All-in-one computer: Setting, displaying, storing and querying test data
Technical parameter
Model | RJ6000 | ||
Ground resistance test | Open circuit output voltage | <12V | |
Output Current Setting | Range/Resolution/Accuracy | 3A~30A / 1A / ±(3%rdg.+0.18A) | |
Current Frequency Setting | Range/Accuracy | 50Hz / 60Hz / ±0.1% | |
Resistance limit setting | Range/Resolution | 3A~10A: 10mΩ~600mΩ / 1mΩ | |
11A~25A:10mΩ~300mΩ / 1mΩ | |||
26A~30A:10mΩ~200mΩ / 1mΩ | |||
Lower resistance limit setting | Range/Resolution | 0mΩ~100mΩ / 1mΩ | |
Time setting | Range/Resolution/Accuracy | 1.0s~999.9s / 0.1s / ±(0.1%st.+0.5dgt.) | |
Resistance Measurement | Range/Resolution/Accuracy | 1mΩ~600mΩ / 1mΩ / ±(3%rdg.+5dgt.) | |
Insulation Resistance Test | Output Capacity | 2VA(1000V/2mA) | |
Output Voltage | Range/Resolution/Accuracy | 200V~1000V / 1V / ±(3%rdg.+3dgt.) | |
Lower resistance limit setting | Range/Resolution | 0.3MΩ~99.9MΩ/100MΩ~3000MΩ/ 0.1MΩ/1MΩ | |
Resistance limit setting | Range/Resolution | 0.0MΩ~99.9MΩ/100MΩ~3000MΩ/ 0.1MΩ/1MΩ | |
Time setting | Range/Resolution/Accuracy | 1.0s~999.9s / 0.1s / ±(0.1%st.+0.5dgt.) | |
Resistance Measurement | Range/Resolution/Accuracy | 1.0 MΩ~99.9MΩ/0.1MΩ/±(3%rdg.+3dgt.) | |
100 MΩ~2000MΩ/ 1MΩ /±(8%rdg.+8dgt.) | |||
AC Voltage Withstand Test | Output Capacity | 100VA(5000V/20mA) | |
Output Voltage | Range/Resolution/Accuracy | 300V~5000V / 1V / ±(3%rdg.+10dgt.) | |
Voltage Frequency | Range/Accuracy | 50Hz / 60Hz / ±0.1% | |
Current lower limit setting | Range/Resolution | 0.00mA~10.00mA /0.01mA | |
Current Upper Limit Setting | Range/Resolution | 0.10mA~20.00mA /0.01mA | |
Time setting | Range/Resolution/Accuracy | 2.0s~999.9s / 0.1s / ±(0.1%st.+0.5dgt.) | |
Current Measurement | Range/Resolution/Accuracy | 0.10mA~20.00mA/0.01mA/±(3%rdg.+3dgt.) | |
DC voltage withstand test | Produced grain weight | 40VA(4000V/10mA) | |
Output Voltage | Range/Resolution/Accuracy | 300V~4000V / 1V /±(3%rdg.+10dgt.) | |
Current lower limit setting | Range/Resolution | 0.000mA~9.999mA /0.001mA | |
Current Upper Limit Setting | Range/Resolution | 0.010mA~9.999mA /0.001mA | |
Time setting | Range/Resolution/Accuracy | 1.0s~999.9s / 0.1s / ±(0.1%st.+0.5dgt.) | |
Current Measurement | Range/Resolution/Accuracy | 0.001mA~9.999mA/0.001mA/±(3%rdg.+5dgt.) | |
Leakage current test | Current lower limit setting | Range/Resolution | 0μA ~9999μA / 1μA |
Current Upper Limit Setting | Range/Resolution | 0μA ~9999μA / 1μA | |
Time setting | Range/Resolution/Accuracy | 2.0s~999.9s / 0.1s/±(1%st.+2dgt.) | |
Voltage measurement | Range/Resolution/Accuracy | 60V~280V / 1V /±(0.5%rdg.+2dgt.) | |
Current Measurement | Range/Resolution/Accuracy | 50μA ~9999μA / 1μA / | |
DC ~10kHz: ±(3%rdg.+10dgt.) | |||
10kHz~ 1MHz: ±(5%rdg.+50dgt.) | |||
Start-up test | Current upper and lower limit settings | Range/Resolution | 0.00A~25.00A / 0.01A |
Time setting | Range/Resolution/Accuracy | 1.0s~999.9s / 0.1s/±(1%st.+2dgt.) | |
Middle Voltage measurement | Range/Resolution/Accuracy | 60V~280V / 1V /±(0.5%rdg.+2dgt.) | |
Current Measurement | Range/Resolution/Accuracy | 0.030A~3.999A /0.001A/±(0.5%rdg.+20dgt.) | |
4.00A~25.00A /0.01A /±(0.5%rdg.+2dgt.) | |||
Power Test | Power upper and lower limit settings | Range/Resolution | 0W~6000W / 1W |
Time setting | Range/Resolution/Accuracy | 1.0s~999.9s / 0.1s/ ±(1%st.+2dgt.) | |
Voltage measurement | Range/Resolution/Accuracy | 60V~280V / 1V / ±(0.5%rdg.+2dgt.) | |
Current Measurement | Range/Resolution/Accuracy | 0.030A~3.999A /0.001A / ±(0.5%rdg.+20dgt.) | |
4.00A~25.00A /0.01A / ±(0.5%rdg.+2dgt.) | |||
Power Measurement | Range/Resolution/Accuracy | 30.0W~199.9W /0.1W / ±(0.5%rdg.+50dgt.) | |
200.0W~6000.0W /0.1W /±(0.5%rdg.+30dgt.) | |||
Power Factor Measurement | Range/Resolution/Accuracy | 0.10~1.00 /0.01 / ±(2%rdg.+2dgt.) | |
Open-short circuit | Resistance upper and lower limit settings | Range/Resolution | 1Ω~500Ω / 1Ω |
Time setting | Range/Resolution/Accuracy | 1.0s~999.9s / 0.1s/ ±(1%st.+2dgt.) | |
Resistance Measurement | Range/Resolution/Accuracy | 1Ω~500Ω / 1Ω / ±(2%rdg.+2dgt.) | |
Other indicators | External Interfaces | RS232, PLC, power supply communication interface, alarm light interface | |
Operating Environment | 0℃~40℃,20%RH~75%RH | ||
Power Supply | AC220V,50/60Hz | ||
Net weight | 25.3kg | ||
External Dimension | 449mm×151mm×600mm(W×HxD) without foot, foot height 15mm | ||
Attachment | 1 instruction manual, 1 power cable (1.5m), 1 communication cable (1.5m), 1 set of test cable. |